GASKETED PLATE HEAT EXCHANGER SUBSTATIONS
Models "Torino" e "Varese"
From 50 to 6.000 kW


Gasketed plate heat exchangers.
50 to 6.000 kW standard package.
With heat meter, control and security devices.
PN 25 on primary circuit.
Twin heat exchanger version (max 5.000 kW).
For hot and superheated water networks.
Heating, cooling and DHW versions.
User customizable. CE / PED Certification.
Small size. Easy to disassemble and move.
Ready for remote metering and remote control.
Flow rate, power and return temperature limitation.
Temperature management for fixed-point or external temperature compensated.
Our models
Hot Water , Heating
|
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pos. |
Model |
Power |
DN 1° |
DN 2° |
PN 1° |
PN 2° |
Tmax 1° |
Tmax 2° |
Dimensions |
Weight |
187 |
TORINO 50 C |
50.00 |
20/20 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
268 |
188 |
TORINO 75 C |
75.00 |
20/20 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
269 |
189 |
TORINO 100 C |
100.00 |
25/20 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
274 |
190 |
TORINO 125 C |
125.00 |
25/25 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
287 |
191 |
TORINO 150 C |
150.00 |
40/25 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
291 |
192 |
TORINO 175 C |
175.00 |
40/25 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
296 |
193 |
TORINO 200 C |
200.00 |
40/40 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
297 |
194 |
TORINO 250 C |
250.00 |
40/40 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
313 |
195 |
TORINO 300 C |
300.00 |
40/40 |
65/65 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
318 |
196 |
TORINO 350 C |
350.00 |
40/40 |
65/65 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
357 |
Hot Water , DHW - Direct
|
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pos. |
Model |
Power |
DN 1° |
DN 2° |
PN 1° |
PN 2° |
Tmax 1° |
Tmax 2° |
Dimensions |
Weight |
197 |
TORINO 50 C ACS D |
50.00 |
20/20 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
265 |
198 |
TORINO 75 C ACS D |
75.00 |
20/20 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
265 |
199 |
TORINO 100 C ACS D |
100.00 |
25/20 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
265 |
200 |
TORINO 150 C ACS D |
150.00 |
40/25 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
281 |
201 |
TORINO 200 C ACS D |
200.00 |
40/40 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
282 |
202 |
TORINO 300 C ACS D |
300.00 |
40/40 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
296 |
Hot Water , DHW - Indirect
|
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pos. |
Model |
Power |
DN 1° |
DN 2° |
PN 1° |
PN 2° |
Tmax 1° |
Tmax 2° |
Dimensions |
Weight |
203 |
TORINO 50 C ACS I |
50.00 |
20/20 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
265 |
204 |
TORINO 75 C ACS I |
75.00 |
20/20 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
266 |
205 |
TORINO 100 C ACS I |
100.00 |
25/20 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
268 |
206 |
TORINO 150 C ACS I |
150.00 |
40/25 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
284 |
207 |
TORINO 200 C ACS I |
200.00 |
40/40 |
50/50 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
287 |
208 |
TORINO 300 C ACS I |
300.00 |
40/40 |
65/65 |
16.00 |
10.00 |
110 |
95 |
1800x600x1650 |
303 |
Hot Water , Heating
|
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pos. |
Model |
Power |
DN 1° |
DN 2° |
PN 1° |
PN 2° |
Tmax 1° |
Tmax 2° |
Dimensions |
Weight |
209 |
TORINO 400 C |
400.00 |
40/50 |
80/80 |
16.00 |
10.00 |
110 |
95 |
2500x600x1650 |
596 |
210 |
TORINO 500 C |
500.00 |
50/50 |
80/80 |
16.00 |
10.00 |
110 |
95 |
2500x600x1650 |
633 |
211 |
TORINO 600 C |
600.00 |
50/65 |
80/80 |
16.00 |
10.00 |
110 |
95 |
2500x600x1650 |
649 |
212 |
TORINO 700 C |
700.00 |
50/65 |
80/80 |
16.00 |
10.00 |
110 |
95 |
2500x600x1650 |
685 |
213 |
TORINO 800 C |
800.00 |
65/65 |
100/100 |
16.00 |
10.00 |
110 |
95 |
2500x600x1650 |
695 |
214 |
TORINO 900 C |
900.00 |
65/65 |
100/100 |
16.00 |
10.00 |
110 |
95 |
2500x600x1650 |
737 |
215 |
TORINO 1000 C |
1000.00 |
65/65 |
100/100 |
16.00 |
10.00 |
110 |
95 |
2500x600x1650 |
747 |
216 |
TORINO 1250 C |
1250.00 |
80/80 |
125/125 |
16.00 |
10.00 |
110 |
95 |
2500x850x1800 |
864 |
217 |
TORINO 1500 C |
1500.00 |
100/100 |
150/150 |
16.00 |
10.00 |
110 |
95 |
2500x850x1800 |
990 |
218 |
TORINO 2000 C |
2000.00 |
100/100 |
150/150 |
16.00 |
10.00 |
110 |
95 |
2500x850x1800 |
1210 |
Overheated Water , Heating
|
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pos. |
Model |
Power |
DN 1° |
DN 2° |
PN 1° |
PN 2° |
Tmax 1° |
Tmax 2° |
Dimensions |
Weight |
226 |
TORINO 50 S |
50.00 |
20/20 |
50/50 |
16.00 |
10.00 |
130 |
95 |
1800x600x1650 |
255 |
227 |
TORINO 75 S |
75.00 |
20/20 |
50/50 |
16.00 |
10.00 |
130 |
95 |
1800x600x1650 |
255 |
228 |
TORINO 100 S |
100.00 |
20/20 |
50/50 |
16.00 |
10.00 |
130 |
95 |
1800x600x1650 |
257 |
229 |
TORINO 125 S |
125.00 |
20/20 |
50/50 |
16.00 |
10.00 |
130 |
95 |
1800x600x1650 |
274 |
230 |
TORINO 150 S |
150.00 |
25/20 |
50/50 |
16.00 |
10.00 |
130 |
95 |
1800x600x1650 |
274 |
231 |
TORINO 175 S |
175.00 |
25/20 |
50/50 |
16.00 |
10.00 |
130 |
95 |
1800x600x1650 |
279 |
232 |
TORINO 200 S |
200.00 |
40/20 |
50/50 |
16.00 |
10.00 |
130 |
95 |
1800x600x1650 |
292 |
233 |
TORINO 250 S |
250.00 |
25/25 |
50/50 |
16.00 |
10.00 |
130 |
95 |
1800x600x1650 |
297 |
234 |
TORINO 300 S |
300.00 |
25/25 |
65/65 |
16.00 |
10.00 |
130 |
95 |
1800x600x1650 |
304 |
235 |
TORINO 350 S |
350.00 |
40/25 |
65/65 |
16.00 |
10.00 |
130 |
95 |
1800x600x1650 |
308 |
236 |
TORINO 400 S |
400.00 |
25/40 |
65/65 |
16.00 |
10.00 |
130 |
95 |
1800x600x1650 |
316 |
237 |
TORINO 500 S |
500.00 |
40/40 |
80/80 |
16.00 |
10.00 |
130 |
95 |
1800x600x1650 |
325 |
Overheated Water , DHW - Direct
|
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pos. |
Model |
Power |
DN 1° |
DN 2° |
PN 1° |
PN 2° |
Tmax 1° |
Tmax 2° |
Dimensions |
Weight |
238 |
TORINO 50 S ACS D |
50.00 |
20/20 |
50/50 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
252 |
239 |
TORINO 75 S ACS D |
75.00 |
20/20 |
50/50 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
252 |
240 |
TORINO 100 S ACS D |
100.00 |
20/20 |
50/50 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
252 |
241 |
TORINO 150 S ACS D |
150.00 |
25/20 |
50/50 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
265 |
242 |
TORINO 200 S ACS D |
200.00 |
25/25 |
50/50 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
281 |
243 |
TORINO 300 S ACS D |
300.00 |
25/25 |
65/65 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
282 |
244 |
TORINO 400 S ACS D |
400.00 |
25/40 |
65/65 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
293 |
245 |
TORINO 500 S ACS D |
500.00 |
40/40 |
65/65 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
298 |
Overheated Water , DHW - Indirect
|
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pos. |
Model |
Power |
DN 1° |
DN 2° |
PN 1° |
PN 2° |
Tmax 1° |
Tmax 2° |
Dimensions |
Weight |
246 |
TORINO 50 S ACS I |
50.00 |
20/20 |
50/50 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
252 |
247 |
TORINO 75 S ACS I |
75.00 |
20/20 |
50/50 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
254 |
248 |
TORINO 100 S ACS I |
100.00 |
20/20 |
50/50 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
255 |
249 |
TORINO 150 S ACS I |
150.00 |
25/20 |
50/50 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
272 |
250 |
TORINO 200 S ACS I |
200.00 |
25/25 |
50/50 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
290 |
251 |
TORINO 300 S ACS I |
300.00 |
25/25 |
65/65 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
295 |
252 |
TORINO 400 S ACS I |
400.00 |
25/40 |
65/65 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
310 |
253 |
TORINO 500 S ACS I |
500.00 |
40/40 |
80/80 |
16.00 |
10.00 |
140 |
95 |
1800x600x1650 |
320 |
Overheated Water , Heating
|
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pos. |
Model |
Power |
DN 1° |
DN 2° |
PN 1° |
PN 2° |
Tmax 1° |
Tmax 2° |
Dimensions |
Weight |
254 |
TORINO 600 S |
600.00 |
40/40 |
80/80 |
16.00 |
10.00 |
130 |
95 |
2500x600x1650 |
627 |
255 |
TORINO 700 S |
700.00 |
40/50 |
80/80 |
16.00 |
10.00 |
130 |
95 |
2500x600x1650 |
631 |
256 |
TORINO 800 S |
800.00 |
40/50 |
100/100 |
16.00 |
10.00 |
130 |
95 |
2500x600x1650 |
678 |
257 |
TORINO 900 S |
900.00 |
40/50 |
100/100 |
16.00 |
10.00 |
130 |
95 |
2500x600x1650 |
681 |
258 |
TORINO 1000 S |
1000.00 |
40/50 |
100/100 |
16.00 |
10.00 |
130 |
95 |
2500x600x1650 |
724 |
259 |
TORINO 1150 S |
1150.00 |
40/65 |
100/100 |
16.00 |
10.00 |
130 |
95 |
2500x600x1650 |
756 |
260 |
TORINO 1300 S |
1300.00 |
50/65 |
100/100 |
16.00 |
10.00 |
130 |
95 |
2500x600x1650 |
804 |
261 |
TORINO 1500 S |
1500.00 |
50/65 |
100/100 |
16.00 |
10.00 |
130 |
95 |
2500x600x1650 |
804 |
262 |
TORINO 2000 S |
2000.00 |
80/80 |
150/150 |
16.00 |
10.00 |
130 |
95 |
2500x850x1800 |
980 |
263 |
TORINO 2500 S |
2500.00 |
80/80 |
150/150 |
16.00 |
10.00 |
130 |
95 |
2500x850x1800 |
1120 |
Hot Water , Heating
|
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pos. |
Model |
Power |
DN 1° |
DN 2° |
PN 1° |
PN 2° |
Tmax 1° |
Tmax 2° |
Dimensions |
Weight |
274 |
VARESE 1000 C |
1000.00 |
80/80 |
100/100 |
16.00 |
10.00 |
110 |
95 |
2800x950x2130 |
3080 |
275 |
VARESE 1250 C |
1250.00 |
100/100 |
100/100 |
16.00 |
10.00 |
110 |
95 |
2800x950x2130 |
3080 |
276 |
VARESE 1500 C |
1500.00 |
100/100 |
125/125 |
16.00 |
10.00 |
110 |
95 |
2800x950x2130 |
3180 |
277 |
VARESE 2000 C |
2000.00 |
100/100 |
125/125 |
16.00 |
10.00 |
110 |
95 |
2800x950x2130 |
3230 |
278 |
VARESE 2500 C |
2500.00 |
125/125 |
150/150 |
16.00 |
10.00 |
110 |
95 |
2800x950x2130 |
3230 |
279 |
VARESE 3000 C |
3000.00 |
125/125 |
150/150 |
16.00 |
10.00 |
110 |
95 |
2800x950x2130 |
3280 |
280 |
VARESE 4000 C |
4000.00 |
150/150 |
200/200 |
16.00 |
10.00 |
110 |
95 |
2800x950x2130 |
3290 |
281 |
VARESE 5000 C |
5000.00 |
150/150 |
250/250 |
16.00 |
10.00 |
110 |
95 |
2800x950x2130 |
3300 |
Overheated Water , Heating
|
||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pos. |
Model |
Power |
DN 1° |
DN 2° |
PN 1° |
PN 2° |
Tmax 1° |
Tmax 2° |
Dimensions |
Weight |
282 |
VARESE 1000 S |
1000.00 |
50/50 |
100/100 |
16.00 |
10.00 |
130 |
95 |
2800x950x2130 |
3050 |
283 |
VARESE 1250 S |
1250.00 |
65/65 |
100/100 |
16.00 |
10.00 |
130 |
95 |
2800x950x2130 |
3050 |
284 |
VARESE 1500 S |
1500.00 |
80/80 |
125/125 |
16.00 |
10.00 |
130 |
95 |
2800x950x2130 |
3150 |
285 |
VARESE 2000 S |
2000.00 |
80/80 |
150/150 |
16.00 |
10.00 |
130 |
95 |
2800x950x2130 |
3200 |
286 |
VARESE 2500 S |
2500.00 |
80/80 |
150/150 |
16.00 |
10.00 |
130 |
95 |
2800x950x2130 |
3200 |
287 |
VARESE 3000 S |
3000.00 |
100/100 |
200/200 |
16.00 |
10.00 |
130 |
95 |
2800x950x2130 |
3250 |
288 |
VARESE 4000 S |
4000.00 |
100/100 |
200/200 |
16.00 |
10.00 |
130 |
95 |
2800x950x2130 |
3250 |
289 |
VARESE 5000 S |
5000.00 |
100/100 |
250/250 |
16.00 |
10.00 |
130 |
95 |
2800x950x2130 |
3250 |
290 |
VARESE 6000 S |
6000.00 |
125/125 |
250/250 |
16.00 |
10.00 |
130 |
95 |
2800x950x2130 |
3350 |
Strength
range and performances
- Complete range from 50 to 6000 kW for district heating and DHW with hot and superheated water networks.
- Ready in stock delivery ready for standard models.
- Mass production ensures high quality level.
- Numerous options available.
construction
- Extremely compact, easy to transport and install.
- Mechanical design primary circuit: PN 25/135 °C standard.
- Primary circuit in accordante with high quality industrial standards (ASTM A106 GR B, tig welded with CE/PED certified x-ray).
- Wells for probes and instruments in Inox AISI 316L steel and flat sealing gasket with Teflon.
- Ready for drainage filter (serial and parallel).
- Ready for installation of optional booster pump.
- Pressure switch and temperature gauges on all circuits.
- Vents and drains on all circuits.
- Special shutter regulation valves for anti-noise district heating applications even with very high deltaP values.
- Galvanization treatment on secondary circuit.
- Metal control board IP 55 with double lock.
- Heat meter inside control board.
- CE/PED approved including also heat exchanger rupture.
- Extension of CE / PED certification to the whole set "Power Station", as an alternative to the Ispesl procedures.
- Wiring and probe cable protected by sheath.
- Amarc DHS components supplier: ALFA LAVAL (heat exchangers) | SIEMENS (heat meters, regulation valves, actuators) | KAMSTRUP (heat meters) | KSB (valves and check valves) | NAVAL OY (ball valves) | IVR (shut-off valves) | CALEFFI (security valve) | SAMSON (self-operated valves) | SALMSON (pumps) | HONEYWELL (actuators, 2-3 port valve)
management
special functions and services
- Metering system sealing and safety lock especially on probes.
- Technical assistance and training.
- Internal Service specialized in district heating with availability on-call service 24/24 h.
- Electrical and mechanical installation.
- Transport and positioning.
- Substation pre-sizing tool application.
- Specifications, diagrams and drawings.
- Preset typical insatallation schemes available.
Common schematic
Working condition
HOT WATER | SUPERHEATED WATER | COOLING | DIRECT H.D.W. (Hot Domestic Water) | INDIRECT H.D.W. (Hot Domestic Water) | |
---|---|---|---|---|---|
THERMAL DESIGN PRIMARY CIRCUIT |
90/65°C | 115/65°C | 7/11°C | 85/55°C | 85/55°C |
THERMAL DESIGN SECONDARY CIRCUIT |
60/75°C | 60/75°C | 14/8°C | 25/50°C | 30/55°C |
PRESSURE LOSS (Δp) @ NOMINAL CONDITIONS - CIRCUITS 1 & 2 |
< 10 w.c.m. (1°) < 3 w.c.m. (2°) |
< 10 w.c.m. (1°) < 3 w.c.m. (2°) |
< 15 w.c.m. (1°) < 6 w.c.m. (2°) |
< 10 w.c.m. (1°) < 3 w.c.m. (2°) |
< 10 w.c.m. (1°) < 3 w.c.m. (2°) |
MECHANICAL DESIGN CIRCUITS 1 & 2 |
PN25 PN16 |
PN16 PN10 |
PN25 PN10 |
||
THERMAL OVERSIZING | 20% | ||||
CERTIFICATION DESIGN | CE/PED - ISPESL | ||||
Δp EMERGENCY CLOSEDOWN REGULATION VALVE |
25 barg | ||||
OPTIMIZATIONS | FLOW RATE LIMITATION, REMOTE SIMULTANEOUS TEMPERATURE AND POWER SETTING |